🧪 Chemistry Calculator Suite Knowledge Base

Magnetic Susceptibility: Gouy Method and Effective Moment

By Aniket Bhardwaj · 10 November 2026 · Inorganic

Magnetic susceptibility measurements provide direct experimental evidence for the electronic structure of coordination compounds. In competitive examinations like CSIR NET, GATE, and IIT-JAM, numerical problems regularly test how to find gram susceptibility from Gouy balance data, apply Pascal diamagnetic corrections, and determine the effective magnetic moment (μeff). These calculations connect laboratory balance readings directly to oxidation states, electron configurations, and ligand field splitting.

Magnetic Susceptibility: Definitions and Unit Systems

When placed in an external magnetic field H, a material acquires an induced magnetization I. The volume magnetic susceptibility is κ = I / H. In CGS-emu, κ has units of emu·cm−3; in SI, κ is dimensionless.

Chemists express susceptibility per gram or per mole:

Textbooks differ between CGS and SI conventions: χM (SI) = 4π × 10−6 × χM (CGS). In coordination chemistry, CGS units (cm3·mol−1) are standard.

Key Susceptibility and Moment Formulas:
χM = χg × M (units: cm3·mol−1)
χMcorr = χMobs − χdia = χMobs + |χdia|
μeff = 2.828 √(χMcorr × T) B.M. (CGS, with T in kelvin)
μeff = √[3kTχM / (μ0NAβ2)] ≈ 797.7 √(χMcorr × T) B.M. (SI)

Principle of the Gouy Balance and Calibration

In the Gouy method, a uniform cylinder of sample of length l and cross-sectional area A hangs vertically between electromagnet poles. The bottom experiences a strong magnetic field H, while the top remains in zero field. Paramagnetic samples are drawn into the field, showing an apparent mass increase (Δm > 0). Diamagnetic samples are repelled, showing an apparent mass loss (Δm < 0).

The magnetic force is F = Δm × g = (1/2) × κ × A × H2. Tubes are calibrated with a known standard, typically mercury tetrathiocyanatocobaltate(II), Hg[Co(NCS)4], with χg,std = 16.44 × 10−6 cm3·g−1 at 293 K.

For an unknown sample packed to the same height as the calibrant:

χg,unk = χg,std × (Δmunk / Δmstd) × (mstd / munk)

Pascal's Constants and Diamagnetic Corrections

Every atom has closed electron shells producing an underlying diamagnetic susceptibility (χdia), which is negative and temperature-independent. The observed molar susceptibility is χMobs = χMpara + χdia.

To obtain the true paramagnetic susceptibility χMcorr of the metal centre, we add the diamagnetic contribution calculated from empirical Pascal's constants: χMcorr = χMobs − χdia = χMobs + |χdia|.

Curie-Weiss Law and Effective Magnetic Moment

Isolated paramagnetic ions obey Curie's law, χMcorr = C / T. With magnetic exchange coupling between centres, compounds obey the Curie-Weiss law: χMcorr = C / (T − θ), where C is the Curie constant and θ is the Weiss constant. Positive θ denotes ferromagnetic coupling, while negative θ denotes antiferromagnetic coupling. When written as (T + θ), positive θ denotes antiferromagnetism.

The effective magnetic moment μeff is compared with the spin-only value μs = √[n(n + 2)] B.M. For A and E ground terms (such as octahedral d3), orbital angular momentum is quenched, so μeff ≈ μs. For T ground terms (such as octahedral d6), orbital contribution is unquenched, making μeff exceed μs.

Exam details

  • Source: practice problem written for this article (not a past-paper question)
  • Relevant exams: CSIR NET, GATE Chemistry, IIT-JAM, CUET-PG
  • Topic: Magnetic Susceptibility, Gouy Method and Effective Moment
  • Difficulty: Advanced

Question: A Gouy tube is calibrated at 293 K with solid Hg[Co(NCS)4] (χg,std = 16.44 × 10−6 cm3·g−1). A mass of 1.500 g of standard gives a mass gain of Δmstd = +24.66 mg. The same tube is packed to identical height with 1.250 g of a nickel(II) complex (molar mass = 288.0 g·mol−1), registering a mass gain of Δmunk = +20.00 mg. Calculate: (a) χg,unk and (b) χMobs.

Step-by-step solution:

Step 1: Write the Gouy calibration equation for equal tube height:

χg,unk = χg,std × (Δmunk / Δmstd) × (mstd / munk)

Step 2: Evaluate the mass change ratio and sample mass ratio:

Δmunk / Δmstd = 20.00 mg / 24.66 mg = 0.81103

mstd / munk = 1.500 g / 1.250 g = 1.200

Step 3: Multiply the standard susceptibility by the ratios:

χg,unk = 16.44 × 10−6 × 0.81103 × 1.200 = 1.600 × 10−5 cm3·g−1

Step 4: Verify with the tube constant K (Route 2):

K = (χg,std × mstd) / Δmstd = (16.44 × 10−6 × 1.500) / 0.02466 = 1.000 × 10−3 cm3

χg,unk = (K × Δmunk) / munk = (1.000 × 10−3 × 0.02000) / 1.250 = 1.600 × 10−5 cm3·g−1

Step 5: Calculate observed molar magnetic susceptibility:

χMobs = χg,unk × M = 1.600 × 10−5 × 288.0 = 4.608 × 10−3 cm3·mol−1

Answer: χg,unk = 1.600 × 10−5 cm3·g−1; χMobs = 4.608 × 10−3 cm3·mol−1

Question: An octahedral chromium(III) complex gives an observed molar susceptibility χMobs = 6.040 × 10−3 cm3·mol−1 at 300.0 K. The Pascal diamagnetic correction is χdia = −2.10 × 10−4 cm3·mol−1. Determine: (a) χMcorr, (b) μeff in Bohr Magnetons, and (c) the number of unpaired electrons by comparing with the spin-only formula.

Step-by-step solution:

Step 1: Write χdia in common scientific notation:

χdia = −0.210 × 10−3 cm3·mol−1

Step 2: Calculate corrected molar susceptibility:

χMcorr = χMobs − χdia = 6.040 × 10−3 − (−0.210 × 10−3) = 6.250 × 10−3 cm3·mol−1

Step 3: Calculate product χMcorr × T:

χMcorr × T = 6.250 × 10−3 × 300.0 = 1.875 cm3·K·mol−1

Step 4: Compute μeff using √(8 × χMcorr × T):

μeff = √(8 × 1.875) = √(15.00) = 3.873 B.M.

Step 5: Verify using the 2.828 factor (Route 2):

μeff = 2.8284 × √(1.875) = 2.8284 × 1.3693 = 3.873 B.M.

Step 6: Compare with spin-only formula μs = √[n(n + 2)]:

For Cr(III), a d3 ion, n = 3 unpaired electrons. μs = √[3(5)] = 3.873 B.M. The experimental μeff equals μs, confirming complete quenching of orbital moment in the 4A2g ground state.

Answer: χMcorr = 6.250 × 10−3 cm3·mol−1; μeff = 3.87 B.M. (matches n = 3 unpaired electrons)

Common Student Mistakes in Magnetic Susceptibility Calculations

  • Subtracting Instead of Adding Diamagnetic Corrections: Because χdia is negative, χMcorr is larger than χMobs (χMcorr = χMobs − χdia = χMobs + |χdia|). Subtracting the magnitude lowers paramagnetic susceptibility.
  • Confusing CGS and SI Units: The relation μeff = 2.828 √(χM × T) requires CGS units (cm3·mol−1). Using SI values directly produces errors by several orders of magnitude.
  • Neglecting Uneven Sample Packing: The Gouy method requires uniform tube packing. Uneven packing produces erratic balance readings and incorrect mass changes.
  • Assuming μeff Always Equals μs: In complexes with T ground terms, unquenched orbital angular momentum increases μeff substantially above √[n(n + 2)].
Competitive Examination Typical Question Format Key Concepts Tested
CSIR NET (Chemical Sciences) Multi-step numerical and conceptual problems Gouy calibration, Pascal corrections, Curie-Weiss plots, orbital quenching
GATE (Chemistry) Numerical Answer Type (NAT) and multiple-choice questions Calculating μeff from χM, finding unpaired electrons, temperature dependence
IIT-JAM (Chemistry) Objective questions on transition metal complexes Spin-only versus effective moment, converting χg to χM, electronic ground terms
CUET-PG Formula-based and conceptual multiple-choice questions Curie law trends, Bohr Magneton units, principles of Gouy balance
Chemistry · CSIR-NET / GATE / IIT-JAM
Practise chemistry questions

Previous-year CSIR-NET questions and timed quizzes to check what you just read.

More Concepts articles