4AB › Chemistry PYQ › CSIR-NET › December 2018 › Q24Q24 · CSIR-NET Chemistry, December 2018 Paper: CSIR-NET December 2018 · Subject: Inorganic Chemistry · Chapter: Analytical Chemistry · Topic: Chromatography · Marks: 2 · Difficulty: Easy
Match the items of Column I with those of Column II. Column-I Column II (A) Laser source (I) Electron Capture Detector (B) Thermometric titration (II) Polarography (C) Gelatin (III) Heat of reaction (D) Gas-liquid chromatography (IV) Spectrofluorimetry
(a) Laser source (I) Electron Capture Detector
(b) Thermometric titration (II) Polarography
(c) Gelatin (III) Heat of reaction
(d) Gas-liquid chromatography (IV) Spectrofluorimetry
Answer Answer: A ✓ checked by 4AB · confidence high
Answer: A–IV, B–III, C–II, D–I.
Explanation Answer: A–IV, B–III, C–II, D–I — Lasers are excitation sources in spectrofluorimetry. A thermometric titration follows the heat of reaction. Gelatin suppresses polarographic maxima. The electron-capture detector is used in GLC.
← Q23 · All questions in this paper · Analytical Chemistry chapter list · Q25 → Study loop for Analytical Chemistry
Open in whiteboard · Browse this chapter in the app